Quickly detect fugitive emissions of organic and inorganic compounds for Method 21 compliance, LDAR applications and site remediation with this lightweight, intrinsically safe portable gas leak detector. The Thermo Scientific™ TVA2020 Toxic Vapor Analyzer can be configured as an FID analyzer (flame ionization detector) or dual detection FID analyzer and PID analyzer (photo ionization detector). Key features include reduced response times, increased user-serviceability, and Bluetooth™ connectivity.
Accuracy | FID Instrument–±10% of reading or ±1.0 ppm, whichever is greater, from 1.0 to 10,000 ppm PID Instrument–±20 % of reading or ±0.5 ppm, whichever is greater, from 0.5 to 500 ppm |
Battery Life | 10 hr. at 0°C |
Battery Type | Lithium Ion |
Calibration Kit | Part Number for FID: CR009UY Part Number for dual detector: CR012UH |
Computer Requirements | USB port, Windows XP operating system or higher |
Concentration | FID: 0-30,000 ppm (methane)PID: 0-2,000 ppm (isobutylene) |
Data Points | Auto mode - 1 per second to 1 per 999 minutes, user selectable VOC or FE Mode - 2 to 30 seconds, user selectable |
Depth (English) | 4 in. |
Depth (Metric) | 10.2 cm |
Description | TVA2020 Toxic Vapor Analyzer |
Detection Limits | The minimum detectable level is defined as seven times the standard deviation of peak-to-peak noise. PID Instrument - 0.5 ppm of isobutylene FID Instrument - 0.5 ppm of methane |
Components Measured | Most Organic and Inorganic Compounds |
Type | FID or PID/FID |
Flow Rate | 1L/min., nominal at sample probe inlet |
Frequency | 50/60 |
Fuel | 99.99% H2 for FID |
Height (English) | 11.5 in. |
Height (Metric) | 29.2 cm |
Inputs | BluetoothTM, USB |
Outputs | BluetoothTM, USB |
Portable Operation Time | Minimum 10 hours |
Repeatability | FID Instrument +/- 2% at 500 ppm of methane PID Instrument +/- 1% at 100 ppm of isobutylene |
Response Time | PID Instrument - Less than 3.5 seconds for 90% of final value, using 500 ppm of isobutylene FID Instrument - Less than 3.5 seconds for 90% of final value, using 10,000 ppm of methane |
Serial Interface | USB |
Temperature Range (English) | 14°F to 113°F |
Temperature Range (Metric) | -10°C - +45°C |
Voltage | 100-230 V |
Warranty | One year from date of shipment |
Weight (English) | FID only 9.2 pounds, Dual 9.4 pounds |
Weight (Metric) | FID only— 4.17 kg Dual— 4.26 kg |
Width (English) | 9 in. |
Width (Metric) | 22.9 cm |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Price (USD) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TVA2020 | Each | TVA2020 Toxic Vapor Analyzer | Request A Quote | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|